Electrical Machines Power Angle Characteristics Synchronous Machines Online Exam Quiz

Electrical Machines Power Angle Characteristics Synchronous Machines GK Quiz. Question and Answers related to Electrical Machines Power Angle Characteristics Synchronous Machines. MCQ (Multiple Choice Questions with answers about Electrical Machines Power Angle Characteristics Synchronous Machines

A 3 phase 400V cylindrical rotor is running at 1500rpm. Suddenly the field excitation zero. Then the net reluctance power is?

Options

A : 0

B : sin 2d

C : cos d

D : cos 2d

View Answer

A synchronous generator is running over excited with a Ef=1.40pu. This machine, with a synchronous reactance of 1.2pu, is delivering a synchronous power of 0.5pu to the bus. If the prime-mover torque is increased by 1%, by how much will the reactive power, Q change?

Options

A : -0.475 %

B : 0.475%

C : 4.75%

D : -4.75%

View Answer

For a 3 phase 400V alternator supplying a load of 0.8 pf lagging at an armature current of 1.1pu. The power delivered to load is?

Options

A : 0.88pu

B : 0.8pu

C : 0.66pu

D : 1.375pu

View Answer

A synchronous generator is operating with a Ef=1.40pu. This machine having Xs of 1.2pu, is delivering a synchronous power of 0.5pu to the bus. If the prime-mover torque is increased by 1%, by how much will the synchronous power P change?

Options

A : 1%

B : 10%

C : -1%

D : 4%

View Answer

For a 3 phase 400V alternator having 0.5pu of synchronous reactance and its excitation voltage of 1.2pu and Vt of 1pu. Then the power delivered to the infinite bus is?

Options

A : 2.4pu

B : 4.8pu

C : 1.44pu

D : 1pu

View Answer

Maximum power in cylinder rotor alternator occurs at load angle of __________

Options

A : 90 degree

B : 45 degree

C : less than 90 degree

D : 180 degree

View Answer

In a synchronous machine, hunting is predominantly damped by __________

Options

A : mechanical losses in the rotor

B : iron losses in rotor

C : copper losses of stator

D : copper losses of rotor

View Answer

The phasor addition of stator and rotor mmfs in a cylindrical rotor synchronous machine, is possible because __________

Options

A : mmfs are rotating in opposite direction

B : mmfs are rotating in same direction at different speeds

C : mmfs are stationary with respect to each other

D : one mmf is stationary and the other mmf is rotating

View Answer

If the synchronous machine is connected to an infinite bus of constant voltage Vt, through a transformed, a transmission line of reactance ‘X’. Then power for a cylindrical machine is?

Options

A : P = (Ef*Vt sin?)/(Xs + X)

B : P = (Ef*Ef sin2?)/(Xs + X)

C : P = (Ef*Vt sin?)/(Xs – X)

D : P = (Vt*Vt sin?)/(Xs + X)

View Answer

A synchronous machine which is synchronized with an infinite bus. If it is desired to obtain a condition when the machine delivers the real power to the IBB without changing the field excitation, then __________

Options

A : reactive power will be consumed by the machine

B : reactive power will be delivered by the machine

C : no reactive power flow will take place

D : none of the mentioned

View Answer

Electrical Machines Action Commutator more Online Exam Quiz

Electrical Machines Operating Characteristics Dc Generator

Electrical Machines Operating Characteristics Dc Motor

Electrical Machines Operating Characteristics Induction Motors

Electrical Machines Permanent Magnet Dc Pmdc Motors

Electrical Machines Physical Concepts Synchronous Machine Operation

Electrical Machines Power Control Three Phase Motors

Electrical Machines Power Factor Control Synchronous Machines

Electrical Machines Power Factor Correction Synchronous Motors

Electrical Machines Power Flow Inductive Impedance

Electrical Machines Principle Operation