Electrical Machines Operating Characteristics Induction Motors GK Quiz. Question and Answers related to Electrical Machines Operating Characteristics Induction Motors. MCQ (Multiple Choice Questions with answers about Electrical Machines Operating Characteristics Induction Motors

A 10 kW, 400 V, 3-phase, 4-pole, 50 Hz induction motor develops the rated output at rated voltage with its slip rings shorted. The maximum torque is twice the full load torque occurs at the slip of 10% with zero external resistance in the rotor circuit. An external resistance is now tripled in the rotor circuit. Then the slip at which maximum torque occur for the same load torque is?

Options

A : 0.3

B : 0.268

C : 0.03

D : 3

View Answer

A 3-phase, 50 Hz, 6-pole induction motor has a shaft output of 10kW at 930 rpm. Friction and windage losses is 1% of the output. Total stator losses is 600W. What is the rotor input?

Options

A : 10860 W

B : 10100 W

C : 11460 W

D : 11000 W

View Answer

A 3-phase, 50 Hz, 6-pole induction motor has a shaft output of 10kW at 930 rpm. Friction and windage losses is 1% of the output. Total stator losses is 600W. What is the stator input?

Options

A : 10860 W

B : 10100 W

C : 11460 W

D : 11000 W

View Answer

A 10 kW, 400 V, 3-phase, 4-pole, 50 Hz induction motor develops the rated output at rated voltage with its slip rings shorted. The maximum torque is twice the full load torque occurs at the slip of 10% with zero external resistance in the rotor circuit. The speed at the full load torque will be?

Options

A : 1460 rpm

B : 1400 rpm

C : 1360 rpm

D : 1470 rpm

View Answer

A 10 kW, 400 V, 3-phase, 4-pole, 50 Hz induction motor develops the rated output at rated voltage with its slip rings shorted. The maximum torque equal to twice the full load torque occurs at the slip of 10% with zero external resistance in the rotor circuit. The slip at the full load torque will be?

Options

A : 2.7%

B : 5%

C : 3.7%

D : 10%

View Answer

For a three phase induction motor, maximum torque is double the full load torque and starting torque is 1.6 times the full load torque. To get a full load slip of 5%, percentage reduction in the rotor resistance should be?

Options

A : 62.7%

B : 75%

C : 60%

D : 35%

View Answer

Mark the stable operating point when the load torque shifts from Tl1 to Tl2.

Options

A : A

B : A,B

C : B,C

D : A,C

View Answer

The stable point in the operation of the induction motor is?

Options

A : C

B : D

C : B

D : A

View Answer

The stable point to use the induction motor possesing the below characteristic.

Options

A : C

B : D

C : C and D

D : Machine will not start

View Answer

A 10 kW, 400 V, 3-phase, 4-pole, 50 Hz induction motor develops the rated output at rated voltage with its slip rings shorted. The maximum torque is twice the full load torque occurs at the slip of 10% with zero external resistance in the rotor circuit. An external resistance is now tripled in the rotor circuit. Then the stator current will _________

Options

A : remain constant

B : increase

C : decrease

D : any of the mentioned

View Answer

Electrical Machines Action Commutator more Online Exam Quiz

Electrical Machines Online Quiz

Electrical Machines Online Test

Electrical Machines Open Circuit Short Circuit Test

Electrical Machines Operating Characteristics Dc Generator

Electrical Machines Operating Characteristics Dc Motor

Electrical Machines Permanent Magnet Dc Pmdc Motors

Electrical Machines Physical Concepts Synchronous Machine Operation

Electrical Machines Power Angle Characteristics Synchronous Machines

Electrical Machines Power Control Three Phase Motors

Electrical Machines Power Factor Control Synchronous Machines