Electrical Machines Power Factor Correction Synchronous Motors Online Exam Quiz

Electrical Machines Power Factor Correction Synchronous Motors GK Quiz. Question and Answers related to Electrical Machines Power Factor Correction Synchronous Motors. MCQ (Multiple Choice Questions with answers about Electrical Machines Power Factor Correction Synchronous Motors

The excess flux in synchronous motor is neutralized by ________

Options

A : armature winding by drawing demagnetizing component of the current from ac supply

B : armature winding by drawing magnetizing component of the current from ac supply

C : field winding by drawing demagnetizing component of the current from dc supply

D : field winding by drawing magnetizing component of the current from dc supply

View Answer

When a constant power output is desired to maintain ________

Options

A : Ef*sin? and Ia*cos? are to be maintained constant

B : Ef*sin? is be maintained constant

C : Ia*cos? is to be maintained constant

D : Ef*sin? and Ia*sin? are to be maintained constant

View Answer

For a power system having induction motor loads, an overexcited synchronous motor is also attached. Then the over all power factor?

Options

A : improves

B : degrades

C : becomes upf

D : remains same

View Answer

For a power system having induction motor loads, an overexcited synchronous motor is also attached. The induction motor will now operate at ________

Options

A : lagging

B : leading

C : reduced power factor

D : increased power factor

View Answer

The armature current is ________ at UPF when compared to leading power factor.

Options

A : minimum

B : maximum

C : equal

D : none of the mentioned

View Answer

When the excitation voltage is increased from 1 to 1.3 pu of a 3-phase synchronous motor. Then load angle for the constant power operation ________

Options

A : must be decreased

B : can also be increased

C : increased

D : decreased

View Answer

Synchronous compensators are ________

Options

A : over excited synchronous motor with no mechanical load

B : over excited synchronous motor with mechanical load

C : under excited synchronous motor with no mechanical load

D : normally excited synchronous motor with no mechanical load

View Answer

The inverted V plots is plotted between ________

Options

A : power factor vs field current for constant shaft load

B : field current vs power factor for variable shaft load

C : armature current vs field current

D : terminal voltage vs power factor

View Answer

Electrical Machines Action Commutator more Online Exam Quiz

Electrical Machines Permanent Magnet Dc Pmdc Motors

Electrical Machines Physical Concepts Synchronous Machine Operation

Electrical Machines Power Angle Characteristics Synchronous Machines

Electrical Machines Power Control Three Phase Motors

Electrical Machines Power Factor Control Synchronous Machines

Electrical Machines Power Flow Inductive Impedance

Electrical Machines Principle Operation

Electrical Machines Questions Bank

Electrical Machines Quiz

Electrical Machines Rotating Amplifiers