Electrical Machines Voltage Regulation Transformer Online Exam Quiz

Electrical Machines Voltage Regulation Transformer GK Quiz. Question and Answers related to Electrical Machines Voltage Regulation Transformer. MCQ (Multiple Choice Questions with answers about Electrical Machines Voltage Regulation Transformer

The voltage regulation for transformer is given by ___________

Options

A : (E2-V2)/E2

B : (E2-V2)/V2

C : (V2-E2)/E2

D : (V2-E2)/V2

View Answer

If the per unit leakage impedance for the primary of a transformer is ‘x’ on the given rated base value. If the voltage and volt-amperes are doubled, then the changed per unit impedance will be ___________

Options

A : 0.5x

B : 2x

C : 4x

D : x

View Answer

If the per unit leakage impedance for the primary of a transformer is ‘x’ on the given rated base value. If the voltage and volt-amperes are halved, then the changed per unit impedance will be ___________

Options

A : 0.5x

B : 2x

C : 4x

D : x

View Answer

If the pu impedance of a single phase transformer is 0.01+j0.05, then its regulation at p.f. of 0.8 lagging will be?

Options

A : 3.8%

B : 2.2%

C : -3.8%

D : -2.2%

View Answer

If the pu impedance of a single phase transformer is 0.01+j0.05, then its regulation at p.f. of 0.8 leading will be?

Options

A : 3.8%

B : 2.2%

C : -3.8%

D : -2.2%

View Answer

A 10 kVA, 400/200 V, 1-phase transformer with 2% resistance and 2% leakage reactance. It draws steady short circuit current at which angle?

Options

A : 45°

B : 75°

C : 135°

D : 0°

View Answer

A 200/400 V single phase transformer has leakage impedance z= r+jx. Then we can expect magnitude of load pf of ____ at zero voltage regulation.

Options

A : cos? = x/z

B : cos? = r/z

C : cos? = x/r

D : cos? = r/x

View Answer

While conducting testing on the single phase transformer, one of the student tries to measure the resistance by putting an ammeter across one terminal of primary and other to secondary, the reading obtained will be ___________

Options

A : infinite

B : zero

C : finite

D : negative finite

View Answer

While conducting open circuit test and short circuit test on a transformer, status of low-voltage and high-voltage windings will be such that in ____________

Options

A : OC test – h.v. open, SC test-l.v. short-circuited

B : OC test – l.v. open, SC test-h.v. short-circuited

C : OC test – l.v. open, SC test-l.v. short-circuited

D : OC test – h.v. open, SC test-h.v. short-circuited

View Answer

While estimating voltage regulation of a transformer, keeping ___________

Options

A : primary voltage constant

B : secondary voltage constant

C : voltage changes constant at primary

D : all of the mentioned

View Answer

Electrical Machines Action Commutator more Online Exam Quiz

Electrical Machines Transformer Constructions

Electrical Machines Transformer Losses Efficiency

Electrical Machines Transformer Phasor Diagram

Electrical Machines Two Reaction Theory Pole Machine

Electrical Machines Voltage Regulation Alternator

Electric Circuits Circuit Containing Dependent Sources

Electric Circuits Experienced

Electric Circuits Freshers

Electric Circuits Inductor Capacitor

Electric Circuits Interview