Design Steel Structures Design Specifications Online Exam Quiz

Design Steel Structures Design Specifications GK Quiz. Question and Answers related to Design Steel Structures Design Specifications. MCQ (Multiple Choice Questions with answers about Design Steel Structures Design Specifications

The effective throat thickness is K times the size of weld. What is the value of K when angle between fusion faces is 80??

Options

A : 0.5

B : 0.65

C : 0.7

D : 1

View Answer

The maximum size of fillet weld is obtained by _______

Options

A : adding 1.5mm to thickness of thinner member to be jointed

B : adding 3mm to thickness of thinner member to be jointed

C : subtracting 3mm from thickness of thinner member to be jointed

D : subtracting 1.5mm from thickness of thinner member to be jointed

View Answer

Which of the following option is incorrect?

Options

A : Effective length of groove weld should not be less than 4 times the weld size

B : Effective length of groove weld should be less than 4 times the weld size

C : Effective length of intermittent weld should not be less than 4 times the weld size

D : Effective length of intermittent weld should have a minimum length 80mm

View Answer

Which of the following is not true regarding effective throat thickness of weld?

Options

A : Effective throat thickness should not be less than 3mm

B : It should not exceed 0.7t or 1t, where t is thickness of thinner plate of elements being welded

C : Effective throat thickness = K x size of weld, where K is a constant

D : Effective throat thickness = K x (size of weld)2 , where K is a constant

View Answer

Effective length of fillet weld is _______

Options

A : equal to overall length plus twice the weld size

B : twice the overall length plus twice the weld size

C : equal to overall length minus twice the weld size

D : twice the overall length minus twice the weld size

View Answer

End returns are made ________

Options

A : equal to twice the size of weld

B : equal to half the size of weld

C : equal to the size of weld

D : equal to thrice the size of weld

View Answer

The minimum size of fillet weld should _______

Options

A : not be less than 3mm

B : be less than 3mm

C : be less than 2mm

D : greater than thickness of thinner part joined

View Answer

The length of overlap of plates to be fillet welded in lap joint ____

Options

A : should not be less than 4 times the thickness of thinner part

B : should be less than 4 times the thickness of thinner part

C : should be less than 2 times the thickness of thinner part

D : should not be less than 2 times the thickness of thinner part

View Answer

What is the minimum specified length of fillet weld?

Options

A : two times the size of weld

B : four times the size of weld

C : six times the size of weld

D : half the size of weld

View Answer

Which of the following are not the assumptions made in the analysis of welded joints?

Options

A : welds connecting various joints are homogenous, isotropic

B : parts connected by weld are rigid

C : only stresses due to internal forces are considered

D : effects of residual stresses are neglected

View Answer

Chemical Engineering Basics - Part 1 more Online Exam Quiz

Design Steel Structures Conditions Plastic Analysis

Design Steel Structures Cross Sectional Classification

Design Steel Structures Deflection Holes Beams

Design Steel Structures Design Compression Members

Design Steel Structures Design Considerations Analysis Methods

Design Steel Structures Design Strength Laterally Supported Beams

Design Steel Structures Design Strength Laterally Unsupported Beams

Design Steel Structures Design Tension Members

Design Steel Structures Design Welds

Design Steel Structures Determination Earthquake Loads