Design Steel Structures Battens Online Exam Quiz

Design Steel Structures Battens GK Quiz. Question and Answers related to Design Steel Structures Battens. MCQ (Multiple Choice Questions with answers about Design Steel Structures Battens

Effective slenderness ratio of battened column shall be ____ of actual slenderness ratio of column

Options

A : 0.5 times

B : 1.1 times

C : 2 times

D : 2.5 times

View Answer

Depth of intermediate batten = _______ depth of end batten

Options

A : 1/2

B : 3/4

C : 1

D : 2

View Answer

Thickness of batten should not be less than

Options

A : 1/40th of distance between innermost connecting lines of bolts

B : 1/50th of distance between innermost connecting lines of bolts

C : 1/100th of distance between innermost connecting lines of bolts

D : 1/10th of distance between innermost connecting lines of bolts

View Answer

Battens should be designed to resist transverse shear force which is

Options

A : 5% of axial force

B : 0.5% of axial force

C : 2.5% of axial force

D : 7.2% of axial force

View Answer

A laced column is_____ than battened column for same load

Options

A : equally strong

B : weaker

C : stronger

D : cannot be compared

View Answer

Which of the following is true about effective depth of end batten?

Options

A : it should be less than distance between centre of gravity of component

B : it should be half the distance between centre of gravity of component

C : it should be less than twice the width of component member

D : it should be greater than twice the width of component member

View Answer

Which of the following is true about effective depth of battens?

Options

A : less than perpendicular distance between centroids for end battens

B : less than three quarters of the perpendicular distance between centroids for intermediate battens

C : not less than twice the width of one member in plane of batten

D : less than twice the width of one member in plane of batten

View Answer

Maximum spacing of batten should be such that slenderness ratio of component member should be

Options

A : not greater than 50

B : greater than 50

C : greater than 0.7 times slenderness ratio of member as a whole

D : greater than slenderness ratio of member as a whole

View Answer

Thickness of batten plates shall be

Options

A : not less than 1/50th of distance between innermost connecting transverse bolts/rivets

B : less than 1/50th of distance between innermost connecting transverse bolts/rivets

C : less than 1/60th of distance between innermost connecting transverse bolts/rivets

D : less than 1/80th of distance between innermost connecting transverse bolts/rivets

View Answer

Which of the following statement is true?

Options

A : Number of battens in a column should be such that member is divided into not less than three bays

B : Number of battens in a column should be such that member is divided into less than three bays

C : Number of battens in a column should be such that member is divided into less than two bays

D : No restriction on number of battens

View Answer

Chemical Engineering Basics - Part 1 more Online Exam Quiz

Design Electrical Machines Window Space Factor

Design Steel Structures Aptitude Test

Design Steel Structures Assessment

Design Steel Structures Back Back Connection

Design Steel Structures Basic

Design Steel Structures Beam Column Splices

Design Steel Structures Beam Types Sections

Design Steel Structures Behaviour Real Beam

Design Steel Structures Bolted Connections

Design Steel Structures Campus Interviews