Design Steel Structures Battens Online Exam Quiz
Design Steel Structures Battens GK Quiz. Question and Answers related to Design Steel Structures Battens. MCQ (Multiple Choice Questions with answers about Design Steel Structures Battens
Effective slenderness ratio of battened column shall be ____ of actual slenderness ratio of column
Options
A : 0.5 times
B : 1.1 times
C : 2 times
D : 2.5 times
Depth of intermediate batten = _______ depth of end batten
Options
A : 1/2
B : 3/4
C : 1
D : 2
Thickness of batten should not be less than
Options
A : 1/40th of distance between innermost connecting lines of bolts
B : 1/50th of distance between innermost connecting lines of bolts
C : 1/100th of distance between innermost connecting lines of bolts
D : 1/10th of distance between innermost connecting lines of bolts
Battens should be designed to resist transverse shear force which is
Options
A : 5% of axial force
B : 0.5% of axial force
C : 2.5% of axial force
D : 7.2% of axial force
A laced column is_____ than battened column for same load
Options
A : equally strong
B : weaker
C : stronger
D : cannot be compared
Which of the following is true about effective depth of end batten?
Options
A : it should be less than distance between centre of gravity of component
B : it should be half the distance between centre of gravity of component
C : it should be less than twice the width of component member
D : it should be greater than twice the width of component member
Which of the following is true about effective depth of battens?
Options
A : less than perpendicular distance between centroids for end battens
B : less than three quarters of the perpendicular distance between centroids for intermediate battens
C : not less than twice the width of one member in plane of batten
D : less than twice the width of one member in plane of batten
Maximum spacing of batten should be such that slenderness ratio of component member should be
Options
A : not greater than 50
B : greater than 50
C : greater than 0.7 times slenderness ratio of member as a whole
D : greater than slenderness ratio of member as a whole
Thickness of batten plates shall be
Options
A : not less than 1/50th of distance between innermost connecting transverse bolts/rivets
B : less than 1/50th of distance between innermost connecting transverse bolts/rivets
C : less than 1/60th of distance between innermost connecting transverse bolts/rivets
D : less than 1/80th of distance between innermost connecting transverse bolts/rivets
Which of the following statement is true?
Options
A : Number of battens in a column should be such that member is divided into not less than three bays
B : Number of battens in a column should be such that member is divided into less than three bays
C : Number of battens in a column should be such that member is divided into less than two bays
D : No restriction on number of battens
Chemical Engineering Basics - Part 1 more Online Exam Quiz
Design Electrical Machines Window Space Factor
Design Steel Structures Aptitude Test
Design Steel Structures Assessment
Design Steel Structures Back Back Connection
Design Steel Structures Beam Column Splices
Design Steel Structures Beam Types Sections
Design Steel Structures Behaviour Real Beam