Dc Machines Ways Reduce Effects Armature Reaction 1 Online Exam Quiz

Dc Machines Ways Reduce Effects Armature Reaction 1 GK Quiz. Question and Answers related to Dc Machines Ways Reduce Effects Armature Reaction 1. MCQ (Multiple Choice Questions with answers about Dc Machines Ways Reduce Effects Armature Reaction 1

What is the ampere turns per pole for compensating winding in DC machines?

Options

A : (pole arc / pole pitch) * armature ampere turns per pole

B : (pole pitch / pole arc) * armature ampere turns per pole

C : (pole arc / pole pitch) * total ampere conductors per pole

D : Cannot be determined

View Answer

What is the exact location of compensating winding?

Options

A : Across armature

B : In series with armature

C : Across armature or in series

D : Cannot be determined

View Answer

Inequality in brush arm currents caused due to different emf induced in different parallel paths may give rise to copper losses. These effects can be avoided by using _________

Options

A : Compensating windings

B : Interpoles

C : Equalizer rings

D : Cannot be determined

View Answer

The armature reaction in a DC machine causes distortion in the main field flux. Effect of armature reaction can be reduced by_________

Options

A : Increasing the length of air gap

B : Decreasing the length of air gap

C : Increasing the number of poles

D : Decreasing the number of poles

View Answer

Exact purpose of compensating winding in a DC generator is _________

Options

A : Mainly to reduce the eddy currents by providing local short-circuits

B : To provide path for the circulation of cooling air

C : To neutralise the cross-magnetising effect of the armature reaction

D : Cannot be determined

View Answer

Function of interpole flux is_________

Options

A : Neutralise the commutating self-induced emf

B : Neutralise the armature reaction flux

C : Neutralise both the armature reaction flux as well as commutating emf induced in the coil

D : Perform none of the above functions

View Answer

In order to neutralize armature mmf perfectly under the pole shoe, the ampere-conductors of compensating winding must be (pole arc/pole pitch=1) _______

Options

A : Not equal to the total armature ampere conductors under the pole shoe

B : Equal to the total armature ampere conductors under the pole shoe

C : Half of the total armature ampere conductors under the pole shoe

D : Twice of the total armature ampere conductors under the pole shoe

View Answer

Which of the following method will completely neutralize the armature reaction in a DC machine?

Options

A : Only compensating winding

B : Only interpoles

C : Compensating winding and interpoles

D : Cannot be determined

View Answer

Where are no equalizer rings connected?

Options

A : Only wave winding

B : Only lap winding

C : Both wave winding and lap winding

D : Cannot be determined

View Answer

The most likely cause(s) of sparking at the brushes in a DC machine is /are ____________

Options

A : Open coil in the armature

B : Defective interpoles

C : Incorrect brush spring pressure

D : Open coil in armature, defective interpoles and incorrect brush spring pressure

View Answer

Dc Machines Applications Dc Machines more Online Exam Quiz

Dc Machines Starting Dc Motors 1

Dc Machines Swinburnes Test

Dc Machines Test

Dc Machines Ward Leonard Speed Control Method

Dc Machines Wave Winding

Differential Calculus Cauchys Mean Value Theorem

Differential Calculus Derivatives Area

Differential Calculus Generalized Mean Value Theorem

Differential Calculus Multiple Choice

Differential Calculus Questions Bank