Biomedical Instrumentation Transmission Video Images Online Exam Quiz

Biomedical Instrumentation Transmission Video Images GK Quiz. Question and Answers related to Biomedical Instrumentation Transmission Video Images. MCQ (Multiple Choice Questions with answers about Biomedical Instrumentation Transmission Video Images

In Coulter counter, for such an aperture, a length of about ______ and flow rate of ______ ml/s would be optimum.

Options

A : 100 u, 0.04

B : 200 u, 0.02

C : 100 u, 0.02

D : 200 u, 0.04

View Answer

In multi-parameter coulter counter, what is the time taken by 1 ml of blood to obtain all parameters?

Options

A : 34 sec

B : 45 sec

C : 34-50 sec

D : 34-45 sec

View Answer

Model ____________ automatically compensates for the loss of pulses during coincidence error.

Options

A : 4008 S Coulter counter

B : S plus Coulter counter

C : A plus Coulter counter

D : 4008 A Coulter counter

View Answer

Under a total count of _______ pulses, primary coincidence is negligible and can be ignored.

Options

A : 5000

B : 1000

C : 8000

D : 10000

View Answer

What is the diameter of Ragweed pollen?

Options

A : 6 micron

B : 19 micron

C : 14 micron

D : 15 micron

View Answer

The diameter of the polystyrene latex particles are ______________________

Options

A : 6 micron

B : 6-20 micron

C : 20 micron

D : 6-14 micron

View Answer

The required bandwidth of the preamplifier used in cell counter must be?

Options

A : 70 kHz

B : 120 kHz

C : 70 Hz

D : 120 Hz

View Answer

What occurs when two or more particles are present in the sensing zone at the same time?

Options

A : Calibration

B : Troubleshooting

C : Delay in results

D : Coincidence error

View Answer

Which following is not constant for the calibration factor in Coulter counter?

Options

A : Electrolyte resistivity

B : Amplifier gain setting

C : Given aperture size

D : Setting of the threshold level control

View Answer

Which of the following is not the provide by multi-parameter coulter counter?

Options

A : Mean cell volume

B : Red cell count

C : Mean cell hemoglobin volume

D : White cell count

View Answer

Biomedical Instrumentation Ambulatory Monitoring Instruments more Online Exam Quiz

Biomedical Instrumentation System Concepts

Biomedical Instrumentation Telemedicine System

Biomedical Instrumentation Test

Biomedical Instrumentation Transmission Digital Audio

Biomedical Instrumentation Transmission Still Images

Biomedical Instrumentation Vectorcardiography Vcg

Biomedical Instrumentation Video Printers

Biomedical Instrumentation Writing System

Bioprocess Engineering Adsorption

Bioprocess Engineering Aerobic Bioprocesses