Which analog-to-digital converter is used in the digitization of ECG signal in signal conditioning?

Options

A : 16 bit

B : 12 bit

C : 32 bit

D : 64 bit

View Answer

What is the sampling rate of the analog-to-digital converter in digitizing of ECG signal in signal conditioning?

Options

A : 250 Hz

B : 215 Hz

C : 40-100 Hz

D : 200-215 Hz

View Answer

In arrhythmia monitoring system, it gives alarm light signals whenever the prematured or widened ectopic beats exist up to the rate of ___________

Options

A : 6/min to 10/min

B : 6/min to 12/min

C : 6/min or 10/min

D : 6/min or 12/min

View Answer

In the process of the ECG waveform, the detection filter removes _______ and _______

Options

A : Baseline wander, motion noise

B : Muscle artifact, motion noise

C : Low frequency noise, motion noise

D : Baseline wander, muscle artifact

View Answer

Which is the final stage in arrhythmia analysis?

Options

A : Beat labeling

B : Alarms

C : Rhythm labeling

D : Summary statistics

View Answer

Which techniques are used in a new algorithm proposed by Jen and Hwang to obtain the long term ECG signal feature and extract the meaningful information hiding in the QRS complex?

Options

A : Cepstrum time warping and Dynamic coefficient

B : Cepstrum coefficient and Dynamic time warping

C : QRS detection and Dynamic coefficient

D : QRS detection and Cepstrum time warping

View Answer

By using a _________ rather than a _________ the amplitude of low frequency noise as well as the low frequency components of the ECG will be reduced without affecting the QRS.

Options

A : High-pass filter, Band-pass filter

B : Low-pass filter, Band-pass filter

C : Band-pass filter, Low-pass filter

D : Band-pass filter, High-pass filter

View Answer

When will be R-R interval declared premature?

Options

A : If it is greater than 85% of the predicted interval

B : If it is less than 85% of the predicted interval

C : If it is greater than 75% of the predicted interval

D : If it is less than 75% of the predicted interval

View Answer

In automated arrhythmia monitoring system, which task is performed after the Ventricular fibrillation detection?

Options

A : Rhythm definition

B : Beat labeling

C : Atrial fibrillation detection

D : Noise detection

View Answer

Ventricular Fibrillation is detected by _________

Options

A : Shape of the QRS complexes

B : Difference of the R-R interval

C : Timing sequence of QRS complexes

D : Frequency domain analysis

View Answer

Biomedical Instrumentation Ambulatory Monitoring Instruments more Online Exam Quiz

Biomedical Instrumentation Optical Fiber Sensors

Biomedical Instrumentation Origin Bioelectric Signals

Biomedical Instrumentation Oximeters

Biomedical Instrumentation Pacs Picture Archiving Communication System

Biomedical Instrumentation Performance Characteristics Transducers

Biomedical Instrumentation Photoelectric Transducers

Biomedical Instrumentation Pneumotachometers

Biomedical Instrumentation Potentiometric Recorder

Biomedical Instrumentation Preamplifiers

Biomedical Instrumentation Pressure Transducers