During humidification process the dry bulb temperature ___

Options

A : increases

B : decreases

C : tends to zero

D : remains the same

View Answer

During the sensible cooling process, specific humidity decreases.

Options

A : TRUE

B : FALSE

C : -

D : -

View Answer

In order to cool and dehumidify a stream of moist air, it must be passed over the coil at a temperature between DBT and WBT.

Options

A : TRUE

B : FALSE

C : -

D : -

View Answer

The minimum temperature to which moist air can be cooled under ideal conditions in a spray washer is ___

Options

A : DPT of inlet air

B : Water inlet temperature

C : WBT of inlet air

D : Water outlet temperature

View Answer

What is the relation between DBT and WBT if the relative humidity is 100%?

Options

A : DBT = WBT

B : DBT > WBT

C : DBT ? WBT

D : DBT < WBT

View Answer

What is the value of Latent heat transfer in a process of humidification having hfg = 10 kJ / kg of dry air, W1 = 0.0071 kJ / kg of dry air and W2 = 0.0017 kJ / kg of dry air?

Options

A : 0.054

B : 0.0054

C : 0.54

D : 5.4

View Answer

What is the value of Latent heat transfer in the process of dehumidification having enthalpies as 19.45 and 13.67 kJ/ kg of dry air respectively?

Options

A : 5.78

B : -5.78

C : 33.12

D : -33.12

View Answer

What is the value of Latent heat transfer in the process of humidification having enthalpies as 20 and 40 kJ / kg of dry air respectively?

Options

A : 60

B : 40

C : -20

D : 20

View Answer

Which of the following denotes dehumidification process on the psychrometric chart?

Options

A : A horizontal line with an arrow towards the right

B : Vertical line with arrow upwards

C : A horizontal line with an arrow towards the right

D : Vertical line with arrow downwards

View Answer

Which of the following denotes Humidification process on the psychrometric chart?

Options

A : A horizontal line with an arrow towards right

B : Vertical line with arrow upwards

C : Horizontal line with an arrow towards right

D : Vertical line with arrow downwards

View Answer

Comfort Air-Conditioning more Online Exam Quiz

Psychrometric Terms

Psychrometry - Adiabatic Mixing of Two Streams

Psychrometry - By-Pass Factor

Psychrometry - Heating and Cooling Factor - 1

Psychrometry - Heating and Cooling Factor - 2

Psychrometry - Inside and Outside Summer Design Conditions

Psychrometry - Thermodynamic Wet Bulb Temperature

Theoretical VCR with Superheated Vapour before and after Compression

Miscellaneous Examples on Fourier Series

Getting Started with OSGi