X-Ray Absorption Meter Online Exam Quiz

X-Ray Absorption Meter GK Quiz. Question and Answers related to X-Ray Absorption Meter. MCQ (Multiple Choice Questions with answers about X-Ray Absorption Meter

Absorption meters cannot be used to detect broken bones.

Options

A : TRUE

B : FALSE

C : -

D : -

View Answer

In absorption meter, the change in thickness of aluminium required for different samples is a function of the difference in which of the following parameters?

Options

A : Amount

B : Concentration

C : Colour

D : Composition

View Answer

In absorption meter, the two halves of the X-ray beam are allowed to fall on which of the following components?

Options

A : Collimator

B : Filter

C : Photomultiplier tube

D : Attenuator

View Answer

In absorption meter, which of the following is adjusted until the absorption of two X-ray beams are brought into balance?

Options

A : Collimator

B : Filter

C : Photomultiplier tube

D : Attenuator

View Answer

In which of the following conditions can thermal conductivity analyzer be used for multi-component mixtures?

Options

A : When all the components have same thermal conductivities

B : When all the components have very different thermal conductivities

C : When all but one component have same thermal conductivities

D : When all components have very different thermal conductivities except two of them which are the same

View Answer

The photomultiplier tube used is absorption meter is coated with which of the following materials?

Options

A : Sodium

B : Potassium

C : Phosphorous

D : Chlorine

View Answer

Thermal conductivity analyzers cannot be used in which of the following measurements?

Options

A : Hydrogen in blast furnace gases

B : Determination of argon in oxygen in the process of air decomposition

C : Sulphur dioxide in roasting gases in production of sulphuric acid

D : Oxygen from a mixture of oxygen and nitrogen

View Answer

Thermistors have positive temperature-coefficient of resistance.

Options

A : TRUE

B : FALSE

C : -

D : -

View Answer

Which among the following elements has the highest thermal conductivity?

Options

A : Nitrogen

B : Oxygen

C : Hydrogen

D : Chlorine

View Answer

Which of the following materials are generally not used for the construction of filaments in thermal conductivity analyzers?

Options

A : Tungsten

B : Gold

C : Platinum

D : Kovar

View Answer

Absorption Instrumentation and Block Diagram Representation more Online Exam Quiz

Tandem Mass Spectroscopy

Thermal Conductivity Analysers

Time of Flight Mass Spectrometer

Total Reflection X-Ray Fluorescence Spectrometer

Types of NMR Spectrometers

X-Ray Diffractometers

X-Ray Fluorescence Spectrometry - Introduction

X-Ray Fluorescent Spectrometer

Array of N-Isotropic Sources

Broadside Array